Voltage 160~260 VAC, 1 phase 2 wire Frequency 50/60 Hz selectable |
Output |
Voltage Max. 170 VDC @ 240 VAC input Current Continuous 5A, Intermittent 7A for 10 sec. Resistance Min. 9Ω Max. 100Ω |
Voltage Regulation |
< ±1% (with 4% engine governing) |
Voltage Build-up |
Residual volts at AVR terminal > 5 VAC |
External Volts Adjustment |
±10% with 5 KΩ 1 watt trimmer |
Unit Power Dissipation |
Max. 8 watt |
Soft Start Ramp Time |
2 sec. |
Thermal Drift |
0.03% per °C change in AVR ambient |
Under Frequency Protection |
For 60 Hz knee point set at 55 Hz For 50 Hz knee point set at 45 Hz |
Environment |
Operating Temperature : -40~65 °C Storage Temperature : -40~80 °C Relative Humidity : Maximum 95% Vibration : 3.3G @ 100~2 KHz |
AVR Controls Function |
VOLTS : Voltage Adjustment STAB : Stability Adjustment U/F*: To Set the U/F Knee Point (*U/F: Under Frequency Protection) |
Dimensions |
150.0 (L) x 100.0 (W) x 74.0 (H) mm |
Weight |
421 g ±2% |