ENVIRONMENTAL TESTING STANDARDS
ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment
ELECTRICAL SAFETY BS EN 60950 Safety of Information Technology Equipment,including Electrical Business Equipment
TEMPERATURE BS EN 60068-2-1 Ab/Ae Cold Test -30 °C BS EN 60068-2-2 Bb/Be Dry Heat +70 °C
VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn
HUMIDITY BS EN 60068-2-30 Db Damp Heat Cyclic 20/55 °C @ 95% RH 48 Hours BS EN 60068-2-78 Cab Damp Heat Static 40 °C
@ 93% RH 48 Hours
SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 mS
DC SUPPLY CONTINUOUS VOLTAGE RATING 8 V to 35 V continuous
CRANKING DROPOUTS Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.
OUTPUTS START Solid state 1.2 A negative grounding terminal
RUN Solid state 1.2 A negative grounding terminal
PRE-HEAT Solid state 1.2 A negative grounding terminal
GENERATOR VOLTAGE RANGE 15 V - 333 V AC (L-N)
FREQUENCY RANGE 3.5 Hz to 75 Hz
DIMENSIONS DSE702 OVERALL 84 mm x 72 mm x 34.9 mm 3.3” x 2.8” x 1.4” Excludes key switch
DSE702 PANEL CUT-OUT 80 mm x 68 mm 3.1” x 2.7”
MAXIMUM PANEL THICKNESS 8 mm 0.3” |