PRECISIONE DI REGOLAZIONE : ±0.5% a regime, per valori di tensione e carico nominali
REGULATION ACCURACY steady state conditions, for rated Voltage and PF
DERIVA TERMICA ±0.5% variazione di tensione per variazione Tamb 50°C
VOLTAGE DRIFT: of voltage change for 50°C T amb change
TEMPO DI RISPOSTA: 1 ciclo (20ms-16.6ms)
RESPONSE TIME: 1 cycle (20ms-16.6ms)
TEMPERATURA DI ESERCIZIO -30°C ÷ +70°C
OPERATING TEMPERATURE:
RESISTENZA DI CAMPO ECCITATRICE 8Ω (min) ÷ 20Ω (max)
EXCITER FIELD RESISTANCE:
DATI DI INGRESSO E USCITA:
INPUT/OUTPUT DATA:
-TENSIONE DI ALIMENTAZIONE: 170 - 270V (50/60Hz)
-SUPPLY VOLTAGE:
-POTENZA DI ALIMENTAZIONE: 350 VA (max)
-POWER SUPPLY:
-POTENZA DISSIPATA: 15 W (max)
-POWER DISSIPATED:
-RILIEVO DI TENSIONE TRIFASE : 170 - 270V
-VOLTAGE SENSING: (Three or Single Phase Sensing)
-TENSIONE DI USCITA (DC): 30V (max, servizio continuo)
-OUTPUT VOLTAGE (DC):
-CORRENTE DI USCITA (DC): 5 A (max, servizio continuo)
-OUTPUT CURRENT (DC): (max, continuous)
-CORRENTE DI USCITA (DC): 8 A (max, in forzamento 1 minuto)
-OUTPUT CURRENT (DC): (max 1 minute forcing)