Voltage 220/380/440 VAC 1 phase 2 wire DIP switch selectable Frequency 50/60 Hz DIP switch selectable |
Power Input |
Voltage 100~300 VAC 1 phase 2 wire |
Output |
Voltage Max. 90 VDC @ 240 VAC input Current Continuous 5A, Intermittent 7A for 10 sec. Resistance Min. 12Ω Max. 100Ω |
Volts Regulation |
< ±0.5% (with 4% engine governing) |
Voltage Build-up |
Residual volts at AVR terminal > 5 VAC |
External Volts Adjustment |
7% with 1 KΩ 1 watt trimmer |
Unit Power Dissipation |
Max. 8 watt |
Soft Start Ramp Time |
2 sec. |
EMI Suppression |
Internal electromagnetic interference filtering |
Thermal Drift |
0.03% per °C change in AVR ambient |
Under Frequency Protection (Factory Setting) |
60 Hz system presets knee point at 55 Hz 50 Hz system presets knee point at 45 Hz |
Environment |
Operating Temperature : -40~70 °C Storage Temperature : -40~85 °C Relative Humidity : Maximum 95% Vibration : 3G @ 100~2 KHz |
AVR Controls Function |
VOLTS : Voltage Adjustment STAB : Stability Adjustment U/F*: To Set the U/F Knee Point (*U/F: Under Frequency Protection) |
Dimensions |
101.0 (L) x 69.0 (W) x 49.5 (H) mm |
Weight |
183 g ±2% |